Wire Sizing Chart 12 volt System

Maximum one way distance (feet) for 5% voltage loss in 12 volt systems.

Wire Size mm

Amps

2.5 mm

4 mm

6 mm

8 mm

16 mm

25 mm

35 mm

50 mm

60 mm

70 mm

85 mm

110

1

106

169

269

427

679

1080

1717

2166

2730

3444

4342

5475

2

53

85

134

214

340

540

859

1083

1365

1722

2171

2738

4

27

42

67

107

170

270

429

542

682

861

1086

1369

6

18

28

45

71

113

180

286

361

455

574

724

913

8

13

21

34

53

85

135

215

271

341

430

543

684

10

11

17

27

43

68

108

172

217

273

344

434

548

15

7

11

18

28

45

72

114

144

182

260

289

365

20

-

8

13

21

34

54

86

108

136

172

217

274

25

-

-

11

17

27

43

69

87

109

138

174

219

30

-

-

9

14

23

36

57

72

91

115

145

183

35

-

-

-

12

19

31

49

62

78

98

124

156

40

-

-

-

-

17

27

43

54

68

86

109

137

45

-

-

-

-

15

24

38

48

61

77

96

122

50

-

-

-

-

14

22

34

43

55

69

87

110

Homepage

Wire Sizing Chart 24 volt System

Maximum one way distance (feet) for 5% voltage loss in 24 volt systems.

Wire Size mm

 

Amps

2.5mm

4mm

6 mm

8 mm

16 mm

25 mm

35 mm

50 mm

60mm   

70 mm

85 mm

110 mm

1

213

338

537

584

1359

2160

3434

4332

5460

6887

8684

10951

2

106

169

269

427

679

1080

1717

2166

2730

3444

4342

5475

4

53

85

134

214

340

540

859

1083

1365

1722

2171

2738

6

35

56

90

142

226

360

572

722

910

1148

1447

1825

8

27

42

67

107

170

270

429

542

682

861

1086

1369

10

21

34

54

85

136

216

343

433

546

689

868

1095

15

14

23

36

57

91

 

 

 

 

 

 

 

Homepage